Home ProductsMagnetic Latching Relay

Zhejiang fanhar electronics co.,ltd

0.2 W Magnetic Latching Relay , Magnetic Control Relay Max Switching Capacity 125VA / 60W

    • 0.2 W Magnetic Latching Relay , Magnetic Control Relay Max Switching Capacity 125VA / 60W
    • 0.2 W Magnetic Latching Relay , Magnetic Control Relay Max Switching Capacity 125VA / 60W
  • 0.2 W Magnetic Latching Relay , Magnetic Control Relay Max Switching Capacity 125VA / 60W

    Product Details:

    Place of Origin: China
    Brand Name: Fanhar
    Certification: TUV UL CQC
    Model Number: W32

    Payment & Shipping Terms:

    Minimum Order Quantity: One Boxful
    Price: Negotiable
    Packaging Details: export carton (58*31*14)cm/2000pcs
    Delivery Time: 10-15 days
    Payment Terms: L/C, T/T
    Supply Ability: 3000,000 pcs per Month
    Contact Now
    Detailed Product Description
    Contact Material: AgSnO2 Installation Type: PCB
    UL Insulation Class: F Weight: 5g
    Dimension: 20.2*10.0*11.5(mm) Contact Arrangement: 2C
    Rated Voltage: 5-24VDC

    0.2 W Magnetic Latching Relay , Max Switching Capacity 125VA / 60W

     

    In different external environments, the impact on the relay is not the same. For example, high temperature / humidity / dust / gas / vibration impact, etc., so select the appropriate product according to the actual environmental conditions.
    1, The temperature of the relay directly affects the life of the relay. The higher the temperature, the shorter life. The general use of the ambient temperature ot relay is 70℃,please refer to the product recommended temperature when using.
    2, Humidity generally affects the contact performance of the relay, which has the greatest impact on the circuit of the tiny current. The wet environment accelerates the oxidation of the contact and the internal metal parts, creating a layer of oxide on the contacts to increase the contact resistance. Under the normal conditions, select the sealed relay when the humidity is greater than 90%.
    3, Dust, gas (including S, NO, HCl, etc.) and more serious environment generally affect the contact performance of the relay. Dust, or gases with S and Ag generated Ag2S attached to the contact surface, resulting in increased contact resistance. Select sealed relay in the case of bad environment.
    4, The environment with serious vibration and impact will affect the reliability of the relay, prone to malfunction or coil disconnection. In general, the vibration resistance of relay is 55HZ (international standard), automotive relay is larger, about 400HZ or 500HZ. So it should give priority to the use of automotive relays if it is used for the equipment with greater impact of vibration

     

    Basic OVERVIEW

    A.Model NO.: W32

    B.Contact Form: 2C = 2 Transformation

    C.Product protective: S=Sealed Nil= Soldered

    D.Contact material: AgNi

    E.Dimension: 20.2*10*11..5 mm

    F.Weight: Approx 5g

    G.Trademark: FANHAR

    H.Origin: China

     

    Product Description
    1. 2A contact switching capability
    2. UL insulation class: F grade

    Contact Data:

    Contact Form 2C
    Rated load 1A 125VAC/ 2A 30VDC
    Max Switching Voltage 250VAC/ 30VDC
    Max Switching Current 2A
    Max Switching Capacity 125VA/60W
    Min Allowing load 10mV 1mA
    Contact Resistance 50mΩ (at 6VDC 1A)
    Insulation Resistance 1000MΩ (at 500VDC)


    General Data:

    Withstand Voltage Between open contacts 750VAC 1min
    Between coil and contacts 1500VAC 1min
    Withstand impact voltage Between coil and contacts 3kv(1.2X50us)
    Operate Time Max.8ms
    Release Time Max.5ms
    Mechanical life 10,000,000 ops ON/OFF = 0.1s/0.1s
    Electrical life 1A 250VAC / 2A 30VDC
    100,000 ops ON/OFF=1s/9s
    Impact Resistance Misoperation
    Durability
    100m/s² Approx10G
    1000m/s² Approx100G
    Vibration Resistance Misoperation
    Durability
    10 - 55 Hz 1.5mm Double Amplitude
    10 - 55 Hz 1.5mm Double Amplitude
    Temperature Range -40ºC to +85ºC
    Humidity 5% to 90%
    Installation type PCB Mounting
    Certification TUV UL CQC


    Coil Data:
    Standard:

    Coil rated voltage Operating
    voltage
    Releasing
    Voltage
    Coil rated
    Current
    (±10%)
    Coil resistance(±10%) Rated consumed power Allowing voltage
    DC 5V Below 75%
    rated voltage (initial)
    above 5%
    rated voltage (initial)
    40mA 125Ω 200mW 90-130 %
    Rated voltage
    DC 6V 33.3mA 180Ω
    DC 9V 22.2mA 405Ω
    DC 12V 16.7mA 720Ω
    DC 15V 13.3mA 1128Ω
    DC 18V 11.1mA 1620Ω
    DC 24V 8.3mA 2880Ω

     