Home ProductsMiniature Power Relay

Electric Meter Miniature Pcb Relay F Grade UL Insulation Class 6g Weight

Electric Meter Miniature Pcb Relay F Grade UL Insulation Class 6g Weight

    • Electric Meter Miniature Pcb Relay F Grade UL Insulation Class 6g Weight
    • Electric Meter Miniature Pcb Relay F Grade UL Insulation Class 6g Weight
    • Electric Meter Miniature Pcb Relay F Grade UL Insulation Class 6g Weight
  • Electric Meter Miniature Pcb Relay F Grade UL Insulation Class 6g Weight

    Product Details:

    Place of Origin: China
    Brand Name: Fanhar
    Certification: TUV UL CQC
    Model Number: W16

    Payment & Shipping Terms:

    Minimum Order Quantity: One Boxful
    Price: Negotiable
    Packaging Details: export carton, 33*28*16(cm) per 1000pcs
    Delivery Time: 10-15 days
    Supply Ability: 3000,000 pcs per Month
    Contact Now
    Detailed Product Description
    Usage: Electric Meter Dimension: Miniature
    Installation Type: PCB Material: AgSnO2
    Size: 20.5*10.5*15.5(mm) Rated Coil Power: 0.2W,0.45W
    Ambient Temperature: -40-80℃ Contact Form: 1A,1C
    Weight: 6g

    PCB Mounting Miniature Power Rely with TUV for electric Power Meter

     

    The majority of the failure of the relay in the application is caused by the load. Due to the actual parameters of the load or application circuit is not fully confirmed, it results in the use of relays with no match, and resulting in the relay contact adhesion, contact wear and tear depletion, contact instability, control circuit occurs to short circuit, performance deterioration of relay insulation, and more severe cases may cause like security risks. Therefore, it is very important to use the relay correctly and safely.

     

    Basic Overview

    A. Model NO.: W16

    B. Contact Form: 1A = 1 OPEN 1B= CLOSE 1C= 1 Switch

    C. Product protective: S=Sealed Nil= Soldered

    D. Contact material: T=AgSnO2 Nil:= AgNi

    E. Coil Power: Nil= Standard L = Sensitive

    F. Load: Nil:Standard Load E=High Load (10A)

    G. Insulation System:Nil:B grade F= F grade

    H. Dimension: 20.5*10.5*15.5 mm

    I. Weight: Approx 6g

    J. Trademark: FANHAR

    K. Origin: China

     

    Product Description
    1. 10A contact switching capability
    2. Creepage distance and spacial distance are greater than 8mm.
    3. UL insulation class : F grade.

    Contact Data:

    Contact Form 1A 1B 1C
    Rated load 10A 250VAC
    5A 250VAC/30VDC
    Max Switching Voltage 277VAC/30VDC
    Max Switching Current 10A
    Max Switching Capacity 2500VA/150W
    Min Allowing load 5VDC 100mA
    Contact Resistance 100mΩ (at 6VDC 1A)
    Insulation Resistance 1000MΩ (at 500VDC)


    General Data:

    Withstand Voltage Between open contacts 1000VAC 1min
    Between coil and contacts 4000VAC 1min
    Withstand impact voltage Between coil and contacts 8kv(1.2X50us)
    Operate Time Max.10ms
    Release Time Max.5ms
    Mechanical life 5,000,000 ops ON/OFF = 0.1s/0.1s
    Electrical life 5A 250VAC/30VDC 50,000 ops ON/OFF=1s/9s
    10A 250VAC 30,000 ops ON/OFF=1s/9s
    3A 250VAC/30VDC 100,000 ops ON/OFF=1s/9s
    Impact Resistance Misoperation
    Durability
    100m/ Approx10G
    1000m/ Approx100G
    Vibration Resistance Misoperation
    Durability
    10 - 55 Hz 1.5mm Double Amplitude
    10 - 55 Hz 1.5mm Double Amplitude
    Temperature Range -40ºC to +85ºC
    Humidity 5% to 90%
    Installation type PCB Mounting
    Certification UL/C-UL:E475405
    TUV:R50346373
    CQC:CQC16002144114


    Coil Data:
    Standard:

    Coil rated voltage Operating
    voltage
    Releasing
    Voltage
    Coil rated
    Current
    (±10%)
    Coil resistance(±10%) Rated consumed power Allowing voltage
    DC 3V Below 75%
    rated voltage (initial)
    above 5%
    rated voltage (initial)
    150mA 20Ω 450mW 90-130 %
    Rated voltage
    DC 5V 90mA 55.5Ω
    DC 6V 75mA 80Ω
    DC 9V 50mA 180Ω
    DC 12V 37.5mA 320Ω
    DC 15V 30mA 500Ω
    DC 18V 25mA 720Ω
    DC 24V 18.8mA 1280Ω
    DC 48V     10.4mA 4608Ω 500mW 90-110 %
    Rated voltage


    Sensitive:

    Coil rated voltage Operating
    voltage
    Releasing
    Voltage
    Coil rated
    Current
    (±10%)
    Coil resistance(±10%) Rated consumed power Allowing voltage
    DC 3V Below 75%
    rated voltage (initial)
    above 5%
    rated voltage (initial)
    66.7mA 45Ω 200mW 90-130 %
    Rated voltage
    DC 5V 40mA 125Ω
    DC 6V 33.3mA 180Ω
    DC 9V 22.2mA 405Ω
    DC 12V 16.7mA 720Ω
    DC 15V 13.3mA 1128Ω
    DC 18V 11.1mA 1620Ω
    DC 24V 8.3mA 2880Ω

     

     

    Contact Details
    Zhejiang fanhar electronics co.,ltd

    Contact Person: Adam

    Tel: +8618257352884

    Send your inquiry directly to us (0 / 3000)