Place of Origin: | China |
Brand Name: | Fanhar |
Certification: | TUV UL CQC |
Model Number: | W27LA |
Minimum Order Quantity: | One Boxful |
---|---|
Price: | Negotiable |
Packaging Details: | export carton,45*30*29(cm)/160pcs |
Delivery Time: | 10- 15 days |
Payment Terms: | L/C, T/T |
Supply Ability: | 3000,000pcs per Month |
Contact Material: | AgSnO2 | Installation Type: | Fast Connection |
---|---|---|---|
Temperature: | -40℃ To +70℃ | Weight: | 70g |
Contact Form: | 1B | Dimension: | 42.0*32.0*20.8(mm) |
Rated Voltage: | 6-24VDC |
New design high Rated Load relay For smart HomeWith UL Certification
In some applications, it is necessary to select a magnet-held relay in order to conserve power when the relay contact is switched on for a long time, and it is often used for short-time driving, so that the relay is held and not driven. In addition, in some stable environments (the temperature does not change, the vibration is not the basic), In addition, in some stable environment (temperature change is not, the impact of vibration is basically no), in order to save electricity, it is often to use maintain pressure. In this case, the magnitude of the buck is generally not less than 50% of the rated voltage. (Such as power monitoring circuit, alarm circuit.)
Basic Overview
A.Model NO.: W27LA
B.Contact Form: 1B = 1 CLOSE
C.Contact material: T=AgSnO2
D.Coil Type: L1= Single Coil L2 = Double Coil
E.Action Polarity: Nil:Standard Polarity R = Reverse Polarity
F.Dimension: 42*32*20.8 mm
G.Weight: Approx 70g
H.Trademark: FANHAR
I.Origin: China
Product Description
1. 120A contact switching capability
2. Only needs pulse excitation, low power consumption and small size.
3. Be able to weld accessories according to clients needs
4. In line with the standard of IEC62055-31: 2005 version.
Contact Data:
Contact Form | 1B |
Rated load | 100A 250VAC |
Max Switching Voltage | 250VAC |
Max Switching Current | 120A |
Max Switching Capacity | 30000VA |
Min Allowing load | 5VDC 100mA |
Contact Resistance | 1.0mΩ (at 6VDC 1A) |
Insulation Resistance | 500MΩ 1Min |
General Data:
Withstand Voltage Between open contacts | 2000VAC 1min |
Between coil and contacts | 4000VAC 1min |
Operate Time | Max.30ms |
Release Time | Max.30ms |
Mechanical life | 5,000,000 ops ON/OFF = 0.1s/0.1s |
Electrical life | 10,000 ops ON/OFF=1s/9s |
Impact Resistance Misoperation Durability |
98m/s² Approx10G 1000m/s² Approx100G |
Vibration Resistance Misoperation Durability |
10 - 55 Hz 1.5mm Double Amplitude 10 - 55 Hz 1.5mm Double Amplitude |
Temperature Range | -40ºC to +70ºC |
Humidity | 5% to 85% |
Installation type | PCB Mounting |
Certification | TUV UL CQC ISO |
Coil Data:
Single Coil:
Coil rated voltage | Operating voltage |
Releasing Voltage |
Coil rated Current (±10%) |
Coil resistance(±10%) | Rated consumed power | Allowing voltage |
DC 6V | Below 75% rated voltage (initial) |
Below 75% rated voltage (initial) |
333mA | 18Ω | 2.0W | 90-150 % Rated voltage |
DC 9V | 222mA | 40.5Ω | ||||
DC 12V | 167mA | 72Ω | ||||
DC 24V | 83mA | 288Ω |
Double Coil:
Coil rated voltage | Operating voltage |
Releasing Voltage |
Coil rated Current (±10%) |
Coil resistance(±10%) | Rated consumed power | Allowing voltage |
DC 6V | Below 75% rated voltage (initial) |
Below 75% rated voltage (initial) |
666/666mA | 9/9Ω | 4.0W |
90-150 % Rated voltage |
DC 9V | 444/444mA | 20.3/20.3Ω | ||||
DC 12V | 334/334mA | 36/36Ω | ||||
DC 24V | 166/166mA | 144/144Ω |