Place of Origin: | China |
Brand Name: | Fanhar |
Certification: | TUV UL CQC |
Model Number: | W32 |
Minimum Order Quantity: | One Boxful |
---|---|
Price: | Negotiable |
Packaging Details: | export carton (58*31*14)cm/2000pcs |
Delivery Time: | 10-15 days |
Payment Terms: | L/C, T/T |
Supply Ability: | 3000,000 pcs per Month |
Contact Material: | AgSnO2 | Installation Type: | PCB |
---|---|---|---|
UL Insulation Class: | F | Weight: | 5g |
Dimension: | 20.2*10.0*11.5(mm) | Contact Arrangement: | 2C |
1A 125VAC Miniature Power Relay With Contact Resistance 50mΩ (at 6VDC 1A)
In different external environments, the impact on the relay is not the same. For example, high temperature / humidity / dust / gas / vibration impact, etc., so select the appropriate product according to the actual environmental conditions.
1, The temperature of the relay directly affects the life of the relay. The higher the temperature, the shorter life. The general use of the ambient temperature ot relay is 70℃,please refer to the product recommended temperature when using.
2, Humidity generally affects the contact performance of the relay, which has the greatest impact on the circuit of the tiny current. The wet environment accelerates the oxidation of the contact and the internal metal parts, creating a layer of oxide on the contacts to increase the contact resistance. Under the normal conditions, select the sealed relay when the humidity is greater than 90%.
3, Dust, gas (including S, NO, HCl, etc.) and more serious environment generally affect the contact performance of the relay. Dust, or gases with S and Ag generated Ag2S attached to the contact surface, resulting in increased contact resistance. Select sealed relay in the case of bad environment.
4, The environment with serious vibration and impact will affect the reliability of the relay, prone to malfunction or coil disconnection. In general, the vibration resistance of relay is 55HZ (international standard), automotive relay is larger, about 400HZ or 500HZ. So it should give priority to the use of automotive relays if it is used for the equipment with greater impact of vibration
Basic Info
Product Description
1. 2A contact switching capability
2. UL insulation class: F grade
Contact Data:
Contact Form | 2C |
Rated load | 1A 125VAC/ 2A 30VDC |
Max Switching Voltage | 250VAC/ 30VDC |
Max Switching Current | 2A |
Max Switching Capacity | 125VA/60W |
Min Allowing load | 10mV 1mA |
Contact Resistance | 50mΩ (at 6VDC 1A) |
Insulation Resistance | 1000MΩ (at 500VDC) |
General Data:
Withstand Voltage Between open contacts | 750VAC 1min |
Between coil and contacts | 1500VAC 1min |
Withstand impact voltage | Between coil and contacts 3kv(1.2X50us) |
Operate Time | Max.8ms |
Release Time | Max.5ms |
Mechanical life | 10,000,000 ops ON/OFF = 0.1s/0.1s |
Electrical life | 1A 250VAC / 2A 30VDC 100,000 ops ON/OFF=1s/9s |
Impact Resistance Misoperation Durability |
100m/s² Approx10G 1000m/s² Approx100G |
Vibration Resistance Misoperation Durability |
10 - 55 Hz 1.5mm Double Amplitude 10 - 55 Hz 1.5mm Double Amplitude |
Temperature Range | -40ºC to +85ºC |
Humidity | 5% to 90% |
Installation type | PCB Mounting |
Certification | TUV UL CQC |
Coil Data:
Standard:
Coil rated voltage | Operating voltage |
Releasing Voltage |
Coil rated Current (±10%) |
Coil resistance(±10%) | Rated consumed power | Allowing voltage |
DC 5V | Below 75% rated voltage (initial) |
above 5% rated voltage (initial) |
40mA | 125Ω | 200mW | 90-130 % Rated voltage |
DC 6V | 33.3mA | 180Ω | ||||
DC 9V | 22.2mA | 405Ω | ||||
DC 12V | 16.7mA | 720Ω | ||||
DC 15V | 13.3mA | 1128Ω | ||||
DC 18V | 11.1mA | 1620Ω | ||||
DC 24V | 8.3mA | 2880Ω |