Place of Origin: | China |
Brand Name: | Fanhar |
Certification: | UL TUV CQC |
Model Number: | W15L |
Minimum Order Quantity: | One Boxful |
---|---|
Price: | Negotiable |
Packaging Details: | export carton, 33*22*16(cm) |
Delivery Time: | 10-15 working days |
Supply Ability: | 3000,000pcs per Month |
Contact Material: | AgSnO2 | Installation Type: | PCB |
---|---|---|---|
Size: | 29*12.7*15.7(mm) | Operate Time: | Max.15ms |
Release Time: | Max.10ms | Temperature: | -40 To +85 |
Coil Latching Relay Be Able To Bear 750A Short-Circuit Inrush Current
DC RELAY coil goes through the DC (U or I), resulting in a constant magnetic field, the power loss is only caused by the heat of the coil. Since the current is constant, the flux is constant and the attraction is constant, so there is no trembling phenomenon, unless the coil voltage fluctuates significantly.
The coil of AC RELAY goes through the AC, resulting in a changed magnetic field (the main flux, leakage flux).
In addition to the coil resistance itself, the heat loss (copper loss), the AC coil also has iron loss (including hysteresis loss, eddy current loss).
AC-RELAY current is alternating, which results that the magnetic flux is also alternating, and the attraction is also changing. So AC-RELAY will have 'hissing' sound. If the voltage fluctuates, the relay will continue to open and close.
Basic Info
Product Description
1. 20A contact switching capability
2. Be able to bear 750A short-circuit inrush current
3. The withstand voltage between coil and contact can reach 10KV.
4. Contact off with manual control switch
5. UL insulation class : F grade
Contact Data:
Contact Form | 1A 1B 1C |
Rated load | 16A 250VAC/30VDC 20A 250VAC |
Max Switching Voltage | 277VA/30VDC |
Max Switching Current | 20A |
Max Switching Capacity | 5000VAC/480W |
Min Allowing load | 5VDC 100mA |
Contact Resistance | 50mΩ (at 6VDC 1A) |
Insulation Resistance | 1000MΩ (at 500VDC) |
General Data:
Withstand Voltage Between open contacts | 1000VAC 1min |
Between coil and contacts | 4000VAC 1min |
Operate Time | Max.15ms |
Release Time | Max.15ms |
Mechanical life | 5,000,000 ops ON/OFF = 0.1s/0.1s |
Electrical life | 16A 250VAC/30VDC 100,000 ops ON/OFF=1s/9s 20A 250VAC/30VDC 50,000 ops ON/OFF=1s/9s |
Impact Resistance Misoperation Durability |
100m/s² Approx10G 1000m/s² Approx100G |
Vibration Resistance Misoperation Durability |
10 - 55 Hz 1.5mm Double Amplitude 10 - 55 Hz 1.5mm Double Amplitude |
Temperature Range | -40ºC to +85ºC |
Humidity | 5% to 90% |
Installation type | PCB Mounting |
Certification | UL/C-UL:E340054 |
Coil Data:
Single coil:
Coil rated voltage | Operating voltage |
Releasing Voltage |
Coil rated Current (±10%) |
Coil resistance(±10%) | Rated consumed power | Allowing voltage |
DC 5V | Below 75% rated voltage (initial) |
Below 75% rated voltage (initial) |
100mA | 50Ω | 500mW | 90-150 % Rated voltage |
DC 6V | 83mA | 72Ω | ||||
DC 9V | 55.6mA | 162Ω | ||||
DC 12V | 41.7mA | 288Ω | ||||
DC 24V | 20.8mA | 1152Ω |
Double coil:
Coil rated voltage | Operating voltage |
Releasing Voltage |
Coil rated Current (±10%) |
Coil resistance(±10%) | Rated consumed power | Allowing voltage |
DC 5V | Below 75% rated voltage (initial) |
Below 75% rated voltage (initial) |
200mA | 25Ω | 1000mW | 90-150 % Rated voltage |
DC 6V | 167mA | 36Ω | ||||
DC 9V | 111mA | 81Ω | ||||
DC 12V | 83mA | 144Ω | ||||
DC 24V | 41.6mA | 576Ω |