Home ProductsGeneral Purpose Power Relay

100A 250VAC 2.0W General Purpose Power Relay , Small Size Electronic Power Relay

100A 250VAC 2.0W General Purpose Power Relay , Small Size Electronic Power Relay

    • 100A 250VAC 2.0W General Purpose Power Relay , Small Size Electronic Power Relay
    • 100A 250VAC 2.0W General Purpose Power Relay , Small Size Electronic Power Relay
    • 100A 250VAC 2.0W General Purpose Power Relay , Small Size Electronic Power Relay
  • 100A 250VAC 2.0W General Purpose Power Relay , Small Size Electronic Power Relay

    Product Details:

    Place of Origin: China
    Brand Name: Fanhar
    Certification: TUV UL CQC
    Model Number: W27LA

    Payment & Shipping Terms:

    Minimum Order Quantity: One Boxful
    Price: Negotiable
    Packaging Details: export carton, 34*23*18(cm) per 160pcs
    Delivery Time: 10- 15 days
    Payment Terms: L/C, T/T
    Supply Ability: 3000,000pcs per Month
    Contact Now
    Detailed Product Description
    Contact Material: AgSnO2 Humidity: 5% To 90%
    Temperature: -40℃ To +85℃ Weight: 70g
    Dimension: 42.0*32.0*20.8 (mm) Contact Arrangement: 1B

    100A 250VAC 2.0W General Purpose Power Relay For Electronic Power Meter

     

    For the relay load, generally it regards pure load as the rated load, and sometimes it will increase the conditions of some inductive load and TV load conditions. It is usually satisfied to use it according to the rated load given by us. But in order to optimize and improve the reliability of the letter patience, we need to use the actual use of derating.
     

    Reference of derived for several typical loads:
    A: Resistive load rating: usually derating 75% of rated capacity
    B: Capacitive load rating: usually derating 75% of the rated load, and it needs to series a resistor to reduce the impact current.
    C: Inductive load rating: usually derating 40% of the rated load, and it needs to use an arc suppression of the absorption circuit.
    D: Motor load rating: Normally the derating is 20% of the rated load, and it needs to adopt a circuit that suppresses the impulse current and the arc is also required.
    E: Tungsten lamp load rating: usually derating 10% of the rated load, and it needs a series of resistance to reduce the impact current.

     

    Basic Info

    1. Model NO.: W27L
    2. Contact Form: 1B = 1 CLOSE
    3. Contact material: T=AgSnO2
    4. Coil Type: L1= Single Coil L2 = Double Coil
    5. Action Polarity: Nil:Standard Polarity R = Reverse Polarity
    6. Dimension: 42*32*20.8 mm
    7. Weight: Approx 70g
    8. Trademark: FANHAR
    9. Origin: China

    Product Description
    1. 120A contact switching capability
    2. Only needs pulse excitation, low power consumption and small size.
    3. Be able to weld accessories according to clients needs
    4. In line with the standard of IEC62055-31: 2005 version.

    Contact Data:

    Contact Form 1B
    Rated load 100A 250VAC
    Max Switching Voltage 250VAC
    Max Switching Current 120A
    Max Switching Capacity 30000VA
    Min Allowing load 5VDC 100mA
    Contact Resistance 1.0mΩ (at 6VDC 1A)
    Insulation Resistance 500MΩ 1Min


    General Data:

    Withstand Voltage Between open contacts 2000VAC 1min
    Between coil and contacts 4000VAC 1min
    Operate Time Max.30ms
    Release Time Max.30ms
    Mechanical life 5,000,000 ops ON/OFF = 0.1s/0.1s
    Electrical life 10,000 ops ON/OFF=1s/9s
    Impact Resistance Misoperation
    Durability
    98m/s² Approx10G
    1000m/s² Approx100G
    Vibration Resistance Misoperation
    Durability
    10 - 55 Hz 1.5mm Double Amplitude
    10 - 55 Hz 1.5mm Double Amplitude
    Temperature Range -40ºC to +70ºC
    Humidity 5% to 85%
    Installation type PCB Mounting
    Certification TUV UL CQC ISO


    Coil Data:
    Single Coil:

    Coil rated voltage Operating
    voltage
    Releasing
    Voltage
    Coil rated
    Current
    (±10%)
    Coil resistance(±10%) Rated consumed power Allowing voltage
    DC 6V Below 75%
    rated voltage (initial)
    Below 75%
    rated voltage (initial)
    333mA 18Ω 2.0W 90-150 %
    Rated voltage
    DC 9V 222mA 40.5Ω
    DC 12V 167mA 72Ω
    DC 24V 83mA 288Ω


    Double Coil:

    Coil rated voltage Operating
    voltage
    Releasing
    Voltage
    Coil rated
    Current
    (±10%)
    Coil resistance(±10%) Rated consumed power Allowing voltage
    DC 6V
    Below 75%
    rated voltage (initial)

    Below 75%
    rated voltage (initial)
    666/666mA 9/9Ω
    4.0W

    90-150 %
    Rated voltage
    DC 9V 444/444mA 20.3/20.3Ω
    DC 12V 334/334mA 36/36Ω
    DC 24V 166/166mA 144/144Ω

    Contact Details
    Zhejiang fanhar electronics co.,ltd

    Contact Person: Michelle

    Tel: +8615157447143

    Send your inquiry directly to us (0 / 3000)