Home ProductsPCB Power Relay

High Sensitivity AgNi Material PCB Power Relay , 5A 250VAC 180mW SPDT PCB Relay

High Sensitivity AgNi Material PCB Power Relay , 5A 250VAC 180mW SPDT PCB Relay

High Sensitivity AgNi Material PCB Power Relay , 5A 250VAC 180mW SPDT PCB Relay

Product Details:

Place of Origin: China
Brand Name: Fanhar
Certification: TUV UL CQC
Model Number: W19F

Payment & Shipping Terms:

Minimum Order Quantity: One Boxful
Price: Negotiable
Packaging Details: export carton, 34*23*18(cm) per 2000pcs
Delivery Time: 10-15 days
Supply Ability: 3000,000 pcs per Month
Contact Now
Detailed Product Description
Usage: General Purpose Dimension: Miniature
Installation Type: PCB Material: AgNi
Operate Time: Max.15ms Release Time: Max.5ms

AgNi Material PCB Power Relay 5A 250VAC With TUV, UL, ROHS For Home Appliance

 

The majority of the failure of the relay in the application is caused by the load. Due to the actual parameters of the load or application circuit is not fully confirmed, it results in the use of relays with no match, and resulting in the relay contact adhesion, contact wear and tear depletion, contact instability, control circuit occurs to short circuit, performance deterioration of relay insulation, and more severe cases may cause like security risks. Therefore, it is very important to use the relay correctly and safely.

 

Basic Info
Model NO.: W19
W19 = Vertical installation W19F = Horizontal Installation
PCB: 1 = type1 2 = type 2
Contact Form: 1A = 1 OPEN
Product protective: S=Sealed Nil= Soldered
Contact material: T=AgSnO2 Nil:= AgNi
Coil Power: Nil= 120mW H = 180mW
Insulation System:Nil:B grade F= F grade
Dimension: 20*5*12.5 mm
Weight: Approx 3g
Trademark: FANHAR
Origin: China
 

Product Description
1. 5A contact switching capability
2. Creepage distance and spacial distance are greater than 3.2mm.
3. UL insulation class : F grade.
4. High sensitivity, coil power is only 120mW.
 

Contact Data:

Contact Form 1A
Rated load 3A 250VAC/30VDC
5A 250VAC/30VDC
Max Switching Voltage 277VAC/30VDC
Max Switching Current 5A
Max Switching Capacity 1250VA/150W
Min Allowing load 5VDC 100mA
Contact Resistance 100mΩ (at 6VDC 1A)
Insulation Resistance 1000MΩ (at 500VDC)

 

General Data:

Withstand Voltage Between open contacts 1000VAC 1min
Between coil and contacts 3000VAC 1min
Withstand impact voltage Between coil and contacts 6kv(1.2X50us)
Operate Time Max.10ms
Release Time Max.5ms
Mechanical life 20,000,000 ops ON/OFF = 0.1s/0.1s
Electrical life 3A 250VAC/30VDC 100,000 ops ON/OFF=1s/9s
5A 250VAC/30VDC 50,000 ops ON/OFF=1s/9s
Impact Resistance Misoperation
Durability
100m/s² Approx10G
1000m/s² Approx100G
Vibration Resistance Misoperation
Durability
10 - 55 Hz 1.5mm Double Amplitude
10 - 55 Hz 1.5mm Double Amplitude
Temperature Range -40ºC to +85ºC
Humidity 5% to 90%
Installation type PCB Mounting
Certification TUV:R50346402
CQC:CQC16002144390

 

Coil Data:
Standard:

Coil rated voltage Operating
voltage
Releasing
Voltage
Coil rated
Current
(±10%)
Coil resistance(±10%) Rated consumed power Allowing voltage
DC 3V
Below 75%
rated voltage (initial)

above 5%
rated voltage (initial)
40mA 75Ω
120mW

90-130 %
Rated voltage
DC 5V 24mA 208.3Ω
DC 6V 20mA 300Ω
DC 9V 13.3mA 675Ω
DC 12V 10mA 1200Ω
DC 15V 8mA 1875Ω
DC 18V 6.7mA 2700Ω
DC 24V 5mA 4800Ω

 

Sensitive:

Coil rated voltage Operating
voltage
Releasing
Voltage
Coil rated
Current
(±10%)
Coil resistance(±10%) Rated consumed power Allowing voltage
DC 3V
Below 75%
rated voltage (initial)

above 5%
rated voltage (initial)
60mA 50Ω
180mW

90-130 %
Rated voltage
DC 5V 36mA 139Ω
DC 6V 30mA 200Ω
DC 9V 20mA 450Ω
DC 12V 15mA 800Ω
DC 15V 12mA 1250Ω
DC 18V 10mA 1800Ω
DC 24V 7.5mA 3200Ω

 

 

Contact Details
Zhejiang fanhar electronics co.,ltd

Contact Person: Michelle

Tel: +8615157447143

Send your inquiry directly to us (0 / 3000)